ขอใบเสนอราคา ขาย AP8653 Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19 ราคา Discount ราคา ถูก โปรโมชั่นพิเศษ ได้ที่นี้
specification
AP8653 Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
Key Features
Output Connections
(3) IEC 60320 C19
(21) IEC 60320 C13
Nominal Output Voltage
230V
Nominal Input Voltage
200V, 208V, 230V
Input Connections
IEC 60309 32 A 2P + E
Cord Length
3meters
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 32A, 230V, (21) C13 & (3) C19
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Includes: CAN port terminator, Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable
- Metering-by-Outlet capability
Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
NetShelter Metered-by-Outlet with Switching Rack PDU Features & Benefits
Availability
Outlet Power Sequencing
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)
Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Metering-by-Outlet capability
Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
Agility
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections
Warranty
Warranty / เงื่อนไขการรับประกัน: ติดต่อสอบถามเพิ่มเติม
Remark
หมายเหตุ
1. รูปสินค้าที่แสดงเป็นเพียงรูปภาพประกอบการขายเท่านั้น
2. ทางบริษัทฯ ขอสงวนสิทธิ์ในการเปลี่ยนแปลงราคาและโปรโมชั่นโดยไม่แจ้งให้ทราบล่วงหน้า
3. ทางบริษัทฯ ขอสงวนสิทธิ์ในการรับผิดชอบใดๆ อันเนื่องจากข้อผิดพลาดจากการนำข้อมูลเข้าสู่หน้า Website เช่น รุ่นสินค้า, รายละเอียดสินค้า, รูปภาพสินค้า เป็นต้น
1. รูปสินค้าที่แสดงเป็นเพียงรูปภาพประกอบการขายเท่านั้น
2. ทางบริษัทฯ ขอสงวนสิทธิ์ในการเปลี่ยนแปลงราคาและโปรโมชั่นโดยไม่แจ้งให้ทราบล่วงหน้า
3. ทางบริษัทฯ ขอสงวนสิทธิ์ในการรับผิดชอบใดๆ อันเนื่องจากข้อผิดพลาดจากการนำข้อมูลเข้าสู่หน้า Website เช่น รุ่นสินค้า, รายละเอียดสินค้า, รูปภาพสินค้า เป็นต้น