Contact
ติดต่อสอบถามเช็คสต็อค, ใบเสนอราคาและงานติดตั้งได้เบอร์ด้านล่างนี้
02-026-6862 Head Office
097-318-6865 Mr. Arnon
097-285-3476 Ms. Maneerat
095-467-6396 Ms. Sunanta
081-774-8189 Admin (Sales)
ติดต่อทางLine@: @Quiznet.co.th
02-026-6862 Head Office
097-318-6865 Mr. Arnon
097-285-3476 Ms. Maneerat
095-467-6396 Ms. Sunanta
081-774-8189 Admin (Sales)
ติดต่อทางLine@: @Quiznet.co.th
Description
ขอใบเสนอราคา ขาย AP8881 Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19 ราคา Discount ราคา ถูก โปรโมชั่นพิเศษ ได้ที่นี้
specification
AP8881 Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19
Key Features
Output Connections
(6) IEC 60320 C19
(36) IEC 60320 C13
Nominal Output Voltage
230V
Nominal Input Voltage
400V 3PH
Input Connections
IEC 60309 16 A 3P + N + PE, IEC 60309 20 A 3P + N + PE
Cord Length
1.8meters
Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Includes: Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable
NetShelter Metered Rack PDUs Features & Benefits
Marketing features
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Agility
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.
Availability
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Warranty
Warranty / เงื่อนไขการรับประกัน: ติดต่อสอบถามเพิ่มเติม
Remark
หมายเหตุ
1. รูปสินค้าที่แสดงเป็นเพียงรูปภาพประกอบการขายเท่านั้น
2. ทางบริษัทฯ ขอสงวนสิทธิ์ในการเปลี่ยนแปลงราคาและโปรโมชั่นโดยไม่แจ้งให้ทราบล่วงหน้า
3. ทางบริษัทฯ ขอสงวนสิทธิ์ในการรับผิดชอบใดๆ อันเนื่องจากข้อผิดพลาดจากการนำข้อมูลเข้าสู่หน้า Website เช่น รุ่นสินค้า, รายละเอียดสินค้า, รูปภาพสินค้า เป็นต้น
1. รูปสินค้าที่แสดงเป็นเพียงรูปภาพประกอบการขายเท่านั้น
2. ทางบริษัทฯ ขอสงวนสิทธิ์ในการเปลี่ยนแปลงราคาและโปรโมชั่นโดยไม่แจ้งให้ทราบล่วงหน้า
3. ทางบริษัทฯ ขอสงวนสิทธิ์ในการรับผิดชอบใดๆ อันเนื่องจากข้อผิดพลาดจากการนำข้อมูลเข้าสู่หน้า Website เช่น รุ่นสินค้า, รายละเอียดสินค้า, รูปภาพสินค้า เป็นต้น